ELR Power Supply Accessories

          Control Module                                        Power Indicator                   (CN1)
          The CM150-08 Control Module is a card that is installed in the ELR150   Green: when power is   Mode Selection Jumper
                                                                present
                                                                                                  For Sequence Mode or Independent
          Series Power Supply and controls one ELR device and includes a Time                     Mode
          Delay Feature. The Time Delay provides a variable Latch Retraction   Fire Indicator
                                                                Blinks Red: fire detected, will
          period in response to a momentary input.              not accept input ON               (CN2-V)
                                                                                                  Time Delay Jumper
          Specifications                                        Red: no fire detected, will       Used to activate Time Delay
          Input                                                 accept input                      when voltage input received
          Switch Input                                          Status Light 2
          •  Normally open                                      Blinks Green:                     (CN2-SW)
                                                                Independent Mode
                                                                                                  Time Delay Jumper
          Voltage Input                                         Double Blinks Green:              Used to activate Time Delay
          •  Input Voltage: 5-24VDC or VAC                      Sequential Mode                   when a switch (dry contact)
                                                                On Green: Latches
                                                                                                  closure is detected
          •  Input Current: approx. 0.005 Amp.                  retracted                           Time Delay
          •  Minimum pulse width: 0.25 seconds                  Status Light 1                      Adjustment
                                                                On Green: input                     Allows for outputs
          Output                                                received                            to continue for  0 - 4
          •  Current Pulse: 4.75 Amp. (2 seconds max.)                                              minutes after input is removed.
                                                                                                    Note: Time Delay is
          •  Continuous: 3.6 VDC / 0.8 Amp.                                                         over ridden when a fire
          Time Delay                                                                                is detected.
          •  User selectable: 0-4 minutes delay after input is removed
          Fire Alarm Terminal
          •  Red LED (D3) blinks when Fire Alarm interrupts circuit
          •  Provides immediate termination of output
            Switch Input:
            •  Accepts normally closed contacts or 5-24 Volts from a
              listed fire detecting device.
            Voltage Input:
            •  Input Current: 0.005 Amp.
            •  Minimum pulse width: 0.25 seconds
          Auxiliary Contacts
          •  Relay isolated contacts provided for remote signaling
           (e.g. door operator)
          •  Normally open or normally closed contacts are rated at 0.5 Amp.,
           24VDC or VAC
          •  Contact operation follows successful operation of the ELR device.
          To Order: specify CM150-08

          Battery Backup                                                    Power Tap
          Power Tap                                                         24VDC 0.8 AMP.
                                                                            For card readers, key pads, mag locks, etc.
          The BT150-07 Battery Backup is an optional card that can          Status Light
          be installed in the ELR150 Series Power Supply to provide         RED: Charging/Monitor
          temporary power to ELR Devices in case of power                   GREEN: Charged Complete
          shortage or outages. Uses (2) 12VDC Lead Acid batteries           Battery Hookup
          (furnished by others). One Amp hour set of batteries              (2) 12 Volt Lead Acid Batteries wired in
          provides approximately 15 minutes of backup to four exit          series (External to Power Supply)
          devices. 24V Power tap is also included to provide power   to
          Card Readers, etc.
          Electrical Ratings – 24 VDC, 0.8 Amp. - Power Tap
          To Order: specify BT150-07