ELR Power Supply Accessories
Control Module Power Indicator (CN1)
The CM150-08 Control Module is a card that is installed in the ELR150 Green: when power is Mode Selection Jumper
present
For Sequence Mode or Independent
Series Power Supply and controls one ELR device and includes a Time Mode
Delay Feature. The Time Delay provides a variable Latch Retraction Fire Indicator
Blinks Red: fire detected, will
period in response to a momentary input. not accept input ON (CN2-V)
Time Delay Jumper
Specifications Red: no fire detected, will Used to activate Time Delay
Input accept input when voltage input received
Switch Input Status Light 2
• Normally open Blinks Green: (CN2-SW)
Independent Mode
Time Delay Jumper
Voltage Input Double Blinks Green: Used to activate Time Delay
• Input Voltage: 5-24VDC or VAC Sequential Mode when a switch (dry contact)
On Green: Latches
closure is detected
• Input Current: approx. 0.005 Amp. retracted Time Delay
• Minimum pulse width: 0.25 seconds Status Light 1 Adjustment
On Green: input Allows for outputs
Output received to continue for 0 - 4
• Current Pulse: 4.75 Amp. (2 seconds max.) minutes after input is removed.
Note: Time Delay is
• Continuous: 3.6 VDC / 0.8 Amp. over ridden when a fire
Time Delay is detected.
• User selectable: 0-4 minutes delay after input is removed
Fire Alarm Terminal
• Red LED (D3) blinks when Fire Alarm interrupts circuit
• Provides immediate termination of output
Switch Input:
• Accepts normally closed contacts or 5-24 Volts from a
listed fire detecting device.
Voltage Input:
• Input Current: 0.005 Amp.
• Minimum pulse width: 0.25 seconds
Auxiliary Contacts
• Relay isolated contacts provided for remote signaling
(e.g. door operator)
• Normally open or normally closed contacts are rated at 0.5 Amp.,
24VDC or VAC
• Contact operation follows successful operation of the ELR device.
To Order: specify CM150-08
Battery Backup Power Tap
Power Tap 24VDC 0.8 AMP.
For card readers, key pads, mag locks, etc.
The BT150-07 Battery Backup is an optional card that can Status Light
be installed in the ELR150 Series Power Supply to provide RED: Charging/Monitor
temporary power to ELR Devices in case of power GREEN: Charged Complete
shortage or outages. Uses (2) 12VDC Lead Acid batteries Battery Hookup
(furnished by others). One Amp hour set of batteries (2) 12 Volt Lead Acid Batteries wired in
provides approximately 15 minutes of backup to four exit series (External to Power Supply)
devices. 24V Power tap is also included to provide power to
Card Readers, etc.
Electrical Ratings – 24 VDC, 0.8 Amp. - Power Tap
To Order: specify BT150-07
22 Apex 2000 Series Touchbar Exit Devices