Exit Alarm

                                                              Weatherized Exit Alarm
                                                              Available for all Apex Series Devices. The Weatherized Exit
                                                              Alarm is identical in operation to the standard Exit Alarm but
                                                              incorporates a weatherized design for use on a variety of
          Exit Alarm                                          applications where contact with the elements may occur.
          Available for all Apex Series Devices               WALW – Remote Powered
          ALK – Battery Operated, provided with a 9 Volt battery and has   12 to 24 VDC at 0.25 Amp., a (2) wire power transfer is required, not
          a audible low battery indicator. Specify WH495 Wire Harness for   furnished standard. Specify WH495 Wire Harness for Remote Arm/
          Remote Arm/Disarm or alternate Input Activation options.   Disarm or alternate Input Activation options.
          ALW – Remote Powered 12 to 24 VDC at 0.25 Amp., a (2) wire power   Weather resistant loss prevention hardware designed for use
          transfer is required, not furnished standard. Specify WH495 Wire   in outdoor or wet environments:
          Harness for External Wire features:                 •  Meets the requirements of MIL-STD 810F, Method 506.4,  Driving
          •  External Arm/Disarm (On/Off)                       Rain Test (simulating 4 in./hr. rain with 40 mph wind)
          •  External Activation (to sound Alarm)             •  Meets the requirements of MIL-STD 810F, Method 509.4, Salt
          The Exit Alarm provides a simple way to audibly monitor the    Fog test (simulating effects of corrosive environments similar to
          use of an exit device. The unit contains a Piezo Alarm which    atmospheric conditions found in costal regions)
          will sound when the touchbar is depressed.  Alarm sounds at 80db   To Order: Device with Weatherized Exit Alarm – add suffix “WALW”
          at 10 feet.                                         to Device No. (e.g. 2108WALW)
          It is also equipped with an LED indicator. The LED flashes   GREEN
          for 20 seconds when the unit is arming and flashes RED every 20
          seconds when the alarm is armed.
          Note: Latch Bolt Monitoring (LS) or Door Position Switch (DS)  is recommended
          when using Alarm option with 2200 Series Surface Vertical Rod devices.
          Cylinder
          The Exit Alarm requires a standard 1-1/4 Mortise Cylinder (for
          cylinder details see page 19) which is used as a key switch to
          perform the following functions:
          •  To turn on (Arm) - it will allow 20 seconds to exit before  ......alarm   Exit Alarm Kit
           sounds.                                            Available for all Apex Devices from 3-0 to 4-0 wide doors. Furnished with
          •  Silence and reset the alarm after unauthorized egress.  Touchbar decal which states:
          •  To turn off (Disarm) the alarm for continuous unmonitored egress.
          •  Engage mechanical Dogging for Non-Fire Rated Devices.
          Wiring Harness - WH495
          Can be wired for one or both of the options listed below.  The Exit Alarm is available in Kits for Retrofit on existing devices. The
          •  Exit Alarm can be turned on (Armed) with alternate inputs. For   channel fillers are different lengths for Narrow and Wide Stile devices. “N”
           other than our DS880 or NDS986 Door Position Switch a (2) wire   denotes Narrow Stile devices.
           power transfer hinge is required (furnished by others).  To Order: Device with Alarm – add suffix “ALK”, “ALW”
          •  Exit alarm can be turned on (Armed) or off (Disarmed) from a   (e.g. 2108ALK)
           remote location. A Cylinder or Dummy Cylinder (by others) is   Alarm Kits
           required. Cylinders are not furnished standard. Specify when   Wide Stile Devices
           required (for cylinder details see page 19).  A (2) wire power   2-6 & 3-0   ALK-3, ALW-3
           transfer is required, not furnished standard.
          To Order: specify WH495                             4-0       ALK-4, ALW-4
                                                              Narrow Stile Devices
                                                              3-0       NALK-3, NALW-3
                                       EXTERNAL ARM/DISARM
                                       (ON/OFF)               4-0       NALK-4, NALW-4
                                       (wire colors: Black and Yellow)  •  WH495 Wiring Harness - Required for External Arming/Disarming the
                                                                Alarm and External Activation to sound the Alarm.
                                       EXTERNAL ACTIVATION    •  Kits are available in finishes 605, 606, 612, 613, 625, 628,  ..........
                                       (TO SIGNAL ALARM)        630. For finish description see page 3.
                                       (wire colors: Black and Red)
                                                              To order: specify Kit No. and finish (e.g. ALK-3  626).
          Note: The Exit Alarm is NOT required when ordering the (DE) Delayed Egress   Note: For Battery operated kits a 9 Volt battery is included.