Monitoring Switches

          Touchbar Monitoring                                 Latchbolt Monitoring
          Available for all Apex Series Devices. The Touchbar Monitoring   Available for Wide Stile Rim, Mortise and Vertical Rod Devices. The
          Switch is an internally mounted switch that is used to   Latchbolt Monitoring Switch is an internally mounted switch that
          signal electromagnetic locks, horns, monitoring stations or   monitors the position of the latchbolt.
          otherelectronic components.                         Mortise LS option monitors auxiliary position. The switch can be used
          •  UL Listed for Panic and Fire for Class II Circuitry.  to signal a monitoring station or an alarm such as a Precision ALK/ALW
          •  TS and TDS can be used in combination with all Apex options   Exit Alarm. For the security of the opening a Door Position Monitoring
            including ELR Devices.                            Switch is recommended.
          TS – (SPDT - Single Pole, Double Throw) version allows for interface   •  UL Listed for Panic and Fire for Class II Circuitry.
          with one external component. A (2) wire power transfer is required,   •  LS and LDS can be used in combination with all Apex
          not furnished standard.                               options including ELR Devices.
          TDS – (DPDT - Double Pole, Double Throw) version allows for   LS – (SPDT - Single Pole, Double Throw) version allows for inter-face
          interface with two external components. A (4) wire power transfer   with one external component. A (2) wire power transfer is required, not
          is required, not furnished standard.                furnished standard.
          To Order: specify prefix TS or TDS (e.g. TS2108)    LDS – (DPDT - Double Pole, Double Throw) version allows for interface
          Touchbar Monitoring Conversion Kit                  with two external components. A (4) wire power transfer is required,
          TS and TDS options are available as kits, specify TSK309 for Single   not furnished standard.
          Switch Monitoring or TDSK310 for Double Switch Monitoring.   To Order: specify prefix LS or LDS (e.g. LS2108)
          Electrical Ratings                                  Latchbolt Monitoring Conversion Kit
          TS – Switch rated to 2 Amps at 24VDC SPDT           LS or LDS option is available as a kit for Wide Stile Devices, specify
          TDS – Switch rated to 2 Amps at 24VDC DPDT          LSRK298 or LDSRK299 for Rim Devices or LSVK910 for Vertical Rod
                                                              Devices. For Mortise Devices see Electric Mortise Lock, page 28.
                                                              Electrical Ratings
          Weatherized Touchbar Monitoring                     LS: Switch rated to 2 Amps at 24VDC SPDT
          Available for all Apex Series Devices. Weatherized Touchbar   LDS: Switch rated to 2 Amps at 24VDC DPDT
          Switch WTS/WTDS is designed for use on a variety of exit device
          applications where contact with the elements may occur. Provided
          with the same specifications as the standard Touchbar monitoring.
          •  Meets the requirements of MIL-STD 810F, Method 506.4, Driving
           Rain Test (simulating 4 in./hr. rain with 40 mph wind)
          •  Meets the requirements of MIL-STD 810F, Method 509.4, Salt
           Fog test (simulating effects of corrosive environments similar to
           atmospheric conditions found in costal regions)
          To Order: specify prefix WTS or WTDS (e.g. WTS2108)
                                                              Door Position Monitoring Switch
                                                              A Magnetic Reed type switch used to monitor the position of a door
                                                              from a remote location. It is mounted in the Touchbar Endcap and
                                                              Door Frame.
                                                              Electrical Ratings 1.5 Amps at 24VDC SPDT
                                                              To Order:
                                                              Wide Stile: specify DS880 and finish.
                                                              Narrow Stile: specify NDS986 and finish.
                                                              Note: The recommended gap between the magnet and the door position switch
                                                              when installed is 1/16” - 1/8”. Please consider the distance between the exit device
                                                              end cap and the frame. Depending on your application, the strike, and the template
                                                              used, the switch and magnet can be adjusted and may extend from the device and/
                                                              or frame. Please consult the factory for installation consideration.