           TIMERS/RELAYS
           —

                                                                                          14-2—7-day programmable timer
                                                                                          with built-in battery for memory
                                                                                          storage up to 100 yr.

                                                                                          Specify 12 V AC/DC or 24 V AC/
                                                                                          DC. One (1) SPDT dry contact, 16
                                                                                          A @ 30 V AC/DC.



                                                                                          TD-ADJ—Adjustable timer acces-
               TDM—Advanced time delay   To sequence vestibule sets of
               module, allowing the installer   doors, unit provides an initial           sory with 0−30 second delay. In-
                                                                                          cludes functionality to change de-
               to use only one time delay for   relay output for the first door,          lay from seconds to minutes
               any automatic door    a delay between outputs 1                            enabling delay of over 24 hours.
               operation, electrically or   and 2, and another output
               magnetically locked doors, or   for the second door. Also
               vestibule sequencing   provides a delay between                            TD-FIX—Fixed 30 second timer
                                                                                          accessory.
               applications.         outputs 2 and 1, allowing
                                     you to sequence your
               Takes one to four inputs and   vestibule in both directions
               converts them to sequential   with only one TDM. Each
               relay outputs.        delay adjustable from 0.0 to                         24-12CONV—Converts 24 VDC
                                                                                          current input to 12 VDC output
                                     99 seconds.
               As a make/break relay,                                                     1.5 A output @ 12 VDC.
               eliminates mechanical     . Power: 12 to 24 V AC/DC                        12-24CONV—Converts 12 VDC
               binding of the locking     Power.
               mechanism on an automatic  . Consumption: 2 W max.                         current input to 24 VDC output
                                                                                          1.5 A output @ 24 VDC.
               door. Make relay can be     . Output Contact: Form C,
               configured as a wet output to   rated @ 3 A.
               directly apply power to an     . Relay Contact Ratings: 3
               electric locking device.   A:120 V AC; 3 A:30 V DC.
                                        . Temperature: –30° C to
                                       70° C (–22° F to 158° F).