Page 43 - Herrajes Patricios - Dorma
P. 43
ELECTRONIC ACCESS CONTROL COMPONENTS ACCESSORIES
Programmable Outputs Operating Features . Keypad locked out after
The keypad features four . System reset. specified number of incorrect
independent outputs with four . Entry code. PIN attempts, from 2–7.
independent timers. Outputs #1 . Adding a new PIN. . Anti-passback time period from
. Erasing a single PIN.
and #2 are Form "C" relay 1–4 minutes or no anti-
contacts. Outputs #3 and #4 are . Erasing all PINs. passback.
solid-state open collector outputs, . Changing the master . Alarm shunt output.
short to common, which are used programming code. . Forced entry output.
to signal forced entry, door ajar, . On-time for each of the four . Door ajar output.
lockout, shunt alarms, request to outputs. . Door sense/inhibit input.
exit, and keypad active conditions. . Beep sounds on key presses. . Keypad active output.
. Beep sound during each of the
four output activation times.
Door Application Typical Door Installation Wiring
Door Sense Switch AC225/AC228
J3 FAIL
SECURE
2 Wires for RELAY N.O. 1
Door Sense #1 COMMON 2 FAIL
SAFE
N.C 3
J4 OUTPUT #3 4 To Alarm
1 ++ OUTPUT #4 5 System
POWER
2 –– N.O. 6
3 DOOR SENSE RELAY COMMON 7
#2
4 COMMON N.C. 8
5 REQUEST-TO-ENTER/EXIT COMMON 9
AC225/ 6 EARTH GROUND GROUND
AC228
Keypad
Request-
to-Exit
2 Wires Alarm Contact OPEN
for Power
Electric
Door Strike
To Alarm
System
Electric Door Strike 2 Wires for From Power Power NOTE: Wiring shown for
Door Strike Supply Supply Door Switch fail secure lock. For fail
safe lock, move wire from
position 1 to position 3.
Available Items
AC200 Keypads
Item Description
AC217 630 (Standard) Keypad, Indoor 120 user code, satin stainless face plate
AC217 605 Keypad, Indoor 120 user code, bright brass face plate
AC225 630 Keypad, Outdoor, 480 user code, satin stainless face plate
AC228 626 Keypad, Indoor, 480 user code, satin chrome face plate
DORMA 43