Motorized Latch Retraction

          PRECISION Motorized Latch Retraction (MLR) exit devices feature the top-quality materials and robust engineering you expect from
          PRECISION, while reducing noise, lowering current requirements, and allowing for longer wire runs compared to power hungry solenoid-
          driven products. Perfect for use in applications that require more flexibility and quieter performance, PRECISION MLR engineering integrates
          easily with existing security frameworks.

           PRECISION MLR Exit Device Specifications
                                   UL-listed panic and fire
                                   UL 305
           Certifications          UL10C
                                   Certified ANSI/BHMA 156.3 Grade 1
                                   FVSU/FVSU7
                                   24 Volts DC @ 1 Amp
                                   Holding current 250mA
           Power Requirements      Note: The MLR initial inrush power requirement is 1Amp. @ 24VDC. Other factors must be taken into consideration when
                                   selecting a power source, i.e. wire run, wire gauge, other electrical loads, etc.
                                   Note: Although PRECISION Power Supplies are not required, RPSMLR2 & RPSMLR2BB Power Supplies are available.
                                   Two brown/white non-polarized power wires
           Wire Count              Two blue/yellow non-polarized sensor wires
                                   Note: Termination of the sensor wires is optional, but provides positive confirmation of latch retraction when used with the RPSMLR2 or
                                   RPSMLR2BB Power Supplies.
                                   2'6" Applications: no field cutting;  2'6" openings ONLY
           Opening Width Range     3'0" Applications: no field cutting; 3'0" openings ONLY
                                   4'0" Applications: field cutting permitted down to 3'4" openings
                                   The MLR option can be ordered as a field retrofit kit to accommodate existing APEX 2000 Series exit devices
                                   MLR can be retrofitted to existing ELR exit devices
           Retrofit Kit            To order the retrofit kit, specify MLR-K
                                   Note: MLR is not compatible with certain product options. For example, MLR is not compatible with mechanical dogging.
                                   Please consult the factory for additional details.
                                   Maximum wire runs between the power supply and device are as follows:
                                   200 feet with 18 gauge wire
           Wire Run                320 feet with 16 gauge wire
                                   500 feet with 14 gauge wire
                                   800 feet with 12 gauge wire