Page 8 - Herrajes Patricios - Dorma
P. 8
ELECTRONIC ACCESS CONTROL COMPONENTS ELECTRIC STRIKES
DORMA ES62 & ES62F 3/4" RIM
ELECTRIC STRIKES
—
Completely surface mounted, . Ensures proper latch
eliminating frame cutting. alignment with horizontal
adjustment up to 1/4"
Designed especially to operate (6.4 mm) to compensate for
with rim exit devices, this rugged door misalignments.
stainless steel strike . Field selectable voltage
accommodates hollow metal, input—12 or 24 VDC, 12 to
aluminum, and wood doors. 24 VAC, 11 to 16 VAC.
The one piece conventional . Horizontal solenoid prevents
keeper design promotes even manipulation from the
load distribution in the event vibration. Lock Down Holes for Conventional Keeper
of attempted forced entry. The . Modular plug-in wire Added Stability (one moving part)
heavy-duty housing of the ES62 connectors for fast hook-up.
is reinforced to eliminate twisting . 630 stainless steel finish.
in the case of imperfect frames. . Non-handed.
The smooth radius corners are . Allen head cap screws for
esthetically pleasing, while added support and tamper- HOW TO ORDER
reducing personal injury due to ES62 & ES62F SERIES
catch hazards. resistance.
. Mounting spacer included to —
Series Voltage
Features provide enhanced latch
. 1500 lb (680 kg) holding engagement. ES — Electric FSV — 12/24 VDC
Field-Selectable
Strike
force.
. No frame cutting required Listings & Approvals ES 62 FSV 630
. UL1034 listed for
—surface mounted. Non Latch Satin
. Conventional keeper design burglary resistance. Fire-Rated — 62 Monitoring — LM 630 — Stainless
. ES62F—3 hour fire-
—promotes even load rated. Fire-Rated — 62F Options Finish
distribution. Model
. Compatible with most exit
Options & Accessories
devices.
. Accommodates exit devices . LM—Latch monitoring option
. DPH62—Double door housing ES62 Specifications
with latch projections from . MSK62—Mounting spacer kit
1/2" to 3/4" (12.7 mm to Mode Voltage Current Duty Sound Amps
19.1 mm). 1/16" (1.5 mm) 12 AC Intermittent Buzz .33
Fail Secure
12 DC Continuous Silent .50
24 AC Intermittent Buzz .64
Fail Secure
24 DC Continuous Silent .24
11 AC Intermittent Buzz .35
Fail Secure
16 AC Intermittent Buzz .50
Intermittent duty = energized less than 1 minute with duty ratio 1:5.
Continuous duty = energized 1 minute or more
Available Items
ES62 & ES62F Electric Strikes (Available in 630 finish only)
Item Description
ES62 FSV 630 Surface mount rim exit strike, UL 1034 (CVXY), 12/24 V
ES62F FSV 630 3 hour fire-rated surface mount rim exit strike, UL 1034 (CVXY), 12/24 V
ES62 FSV LM 630 Surface mount rim exit strike with Latch Monitor switch, UL 1034 (CVXY), 12/24 V
ES62F FSV LM 630 Fire rated surface mount rim exit strike with Latch Monitor switch, UL 1034 (CVXY), 12/24 V
ES62 & ES62F Accessories
DPH62 Door pair housing, ES62, 628 finish only
MSK62 Shim mounting kit, ES62
8 DORMA