ELECTRONIC ACCESS CONTROL COMPONENTS POWER SUPPLIES
Optional Accessories
TD Time Delay Relay Module Trigger voltage must be the
When triggered, the optional TD same as the lock and supply
module will unlock a door for a voltage.
field adjustable time of 1 to 120 . Anti-Tailgate/Reset Input: N.O.
seconds. A reset trigger from a Dry; When the door opens the
door position switch can be used magnetic contact closes,
to terminate the time delay and resetting the timer. The door
relock the door. locks when closed.
. Voltage Output: Fused SPDT, 5
. Input Voltage: 12 or 24 VDC. A @ 30 VDC.
. Input Current: 35 mA. . Relay Output: Non-fused SPDT
TD
. Dry Trigger Inputs: One—N.O. Dry, 5 A @ 30 VDC.
Dry, One—N.C. Dry. . Dimensions: 3.25" W x 2" H.
. Wet Trigger Input: Normally off;
CR4 Four Station . Input Voltage: 12 or 24 VDC.
Control Relay Module . Input Current: 120 mA.
The optional CR4 module . Trigger Inputs: Four N.O. Dry.
provides control of four (4) . Fused Relay Outputs: Four,
stations. Closing a switch across Fused SPDT Dry, 2 A @ 30
the dry trigger input for station A, VDC.
B, C, or D will release the output . Non-fused Relay Outputs:
for the amount of time that the Four, Non-fused, SPDT, Dry, 2
trigger input is held closed. Can A @ 30 VDC.
be used to indicate status or . Dimensions: 6" W x 3.25" H.
implement multiple door
interlocks. The total current of all
CR4 outputs cannot exceed the power
supply rating.
FB-4 Fused Terminal Board determined by the load current of
The optional FB-4 provides four each output. The total current of
(4) individually fused outputs for all outputs cannot exceed the
modular system protection. The power supply rating.
fuse rating for each output is
FB-4
UR2-4 . Latch multistation zones Output Specification
Field programmable 2 door on/off or all stations on/off. . Field selectable voltage
controller, 6 Selectable . Time delay relay 1–60 output or dry contact.
Output Modes. seconds. . Outputs individually
. Dual function latching on/ configured as a dry contact
Each output may be off, plus 1–60 second or 12 or 24 VDC voltage
individually programmed with timed output when on. output, (1) normally (on)
its own mode of operation. . Emergency release input and 1 normally (off).
may control select stations . 2 fused SPDT relays, 5 A @
. Conventional relay. or all stations. 30 VDC.
. Latching relay, on/off. . 2 non-fused SPDT relays, 5
A @ 30 VDC.