40HM IDH Max  – Functions
                             ®

            Function           Latch                        Outside Knob/Lever                 Inside Knob/Lever
                      Operated by             Locked by          Unlocked by              Locked by   Unlocked by
          DEL–Locked  •  Outside knob/lever when power is   Applying power to the   Removing power from the solenoid  Cannot be locked  Always unlocked
          Fail Safe   removed from the solenoid  solenoid; remains locked
                      • Outside key           while power is on.
                      •  Inside knob/lever
                      Latchbolt is deadlocked by an
                      auxiliary latch
                      Powered by 12V DC. temperature control module is not needed.
          DEU–Unlocked  •  Outside knob/lever when power is   Removing power from the   Applying power to the solenoid; remains  Cannot be locked  Always unlocked
          Fail Secure  applied from the solenoid  solenoid       unlocked while power is on.
                      • Outside key
                      •  Inside knob/lever
                      Latchbolt is deadlocked by an
                      auxiliary latch
                      Powered by 12V DC. temperature control module is not needed.
          NXEL–Locked  •  Outside knob/lever when power is   Applying power to the  Removing power from the solenoid  Cannot be locked  Always unlocked
          Fail Safe   removed from the solenoid  solenoid; remains locked
                      • Outside key           while power is on.
                      •  Inside knob/lever
                      Latchbolt is deadlocked by an
                      auxiliary latch
                      Powered by 12V DC. temperature control module is not needed.
          NXEU– Unlocked •  Outside knob/lever when power is   Removing power from the   Applying power to the solenoid; remains  Cannot be locked  Always unlocked
          Fail Secure  applied from the solenoid  solenoid       unlocked while power is on.
                      • Outside key
                      •  Inside knob/lever
                      Latchbolt is deadlocked by an
                      auxiliary latch
                      Powered by 12V DC. temperature control module is not needed.
          TDEL–Locked  • Outside key          Applying power to the   Removing power from the solenoid   Cannot be locked  Always unlocked
          Fail Safe   •  Outside knob/lever when       solenoid; remains locked   Deadbolt and Latchbolt retracted
                      power is removed from the    while power is on.  simultaneously by:
                      solenoid.               Deadbolt operated by:  • Inside knob/lever
                      •  Inside knob/lever    • Outside key      •  Outside knob/lever when power
                      Latchbolt is deadlocked by an    • Inside thumb turn  is removed
                      auxiliary latch
                      Powered by 12V DC. temperature control module is not needed.
          TDEU–Unlocked •  Outside knob/lever when power is   Removing power from the   Applying power to the solenoid; remains  Cannot be locked  Always unlocked
          Fail Secure  applied from the solenoid  solenoid       unlocked while power is on.
                      • Outside key           Deadbolt operated by:  Deadbolt and Latchbolt retracted
                      •  Inside knob/lever    • Outside key      simultaneously by:
                      Latchbolt is deadlocked by an    • Inside thumb turn  • Inside knob/lever
                      auxiliary latch                            •  Outside knob/lever when power is
                                                                 applied
                      Powered by 12V DC. temperature control module is not needed.
          LEL–Locked  •  Outside knob/lever when power is   Applying power to the   Removing power from the solenoid  Cannot be locked  Always unlocked
          Fail Safe   removed from the solenoid  solenoid; remains locked   Deadbolt retracted by:
                      •  Inside knob/lever    while power is on.  • Inside thumb turn
                      Latchbolt is deadlocked by an    Deadbolt extended by:  •  Inside knob/lever retracts the deadbolt
                      auxiliary latch         Inside thumb turn  and latchbolt simultaneously
                                                                 • Outside lever when power is removed
                      Powered by 12V DC. temperature control module is not needed.
          LEU– Unlocked  •  Outside knob/lever when power is   Removing power from the   Applying power to the solenoid; remains  Cannot be locked  Always unlocked
          Fail Secure  removed from the solenoid  solenoid       locked while power is on.
                      • Outside key           Deadbolt extended by:  Deadbolt retracted by:
                      • Inside knob/lever     Inside thumb turn  • Inside thumb turn
                      Latchbolt is deadlocked by an              •  Inside knob/lever retracts the deadbolt
                      auxiliary latch                            and latchbolt simultaneously
                                                                 •  Outside knob/lever when power is
                                                                 applied
                      Powered by 12V DC. temperature control module is not needed.
          Shading indicates a ridged lever/knob in a non-energized state.
                                                                      W & M Series IDH MAX  & Electromechanical Locks  5
                                                                                     ®
   1   2   3   4   5   6   7   8   9   10