Technical Details
          Switch Settings                           Setting                   On              Off
          Factory default settings for normal operation;     1. Electric strike logic  fail secure  fail safe
          all switches on the DIP switch are set to OFF.  2. Electric strike  enabled         disabled
                                                    3. PUSH side/PULL side    PULL side       PUSH side
                                                    4. PUSH and GO            enabled         disabled
                                                    5. Power close            enabled         disabled
                                                    6. N/A
                                                    7. N/A
                                                    8. N/A



















               Controller
              1      2     10     11   12    21    16   13            17      18     19      20




























           3    15    4     5      6     7     8     9   14
          1. TB-1                              7. Self test button               14. Pot #6 open sweep speed
          2. TB-3                              8. Pot #2 Full open position adjustment  15. Pot #5 open check speed
          3. TB-2                              9. Pot #4 Stall force             16. Encoder plug input
          4. Pot #3 not used                  10. DIP switches (See chart above)  17. AC power in
          5.  Pot #1 Hold open time 0-28 seconds.   11. Digital readout          18. Fuse
            Must be a minimum of 5 seconds after   12.  Pot #7 opening torque, only needs   19. N/A
            door fully open                      changed for use on heavier doors  20. Motor socket
          6.  Pot #9 Vestibule time delay     13. Pot #8 not used                21. N/A


                                                                                 Low Energy Operator D-4990     9